I'm trying to configure the UPS serial port on the core i/o of an 
N4000 in order to specify certain actions to take in the event of 
power interruption.

Following is more information:

>PUB:upsutil.mpexl.telesup
>UPS Utility Program  A.02.00   (c) COPYRIGHT Hewlett-Packard Co. 1994, 2001
>
>UPSUTIL Program:  Commands available are as follows:
>
>   (There are no parameters for any of the commands.
>    At the prompt, just type the command name.      )
>
>  Cmd Name:     Command Function:
>  ~~~~~~~~~     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
>   help       - Show this menu of commands.
>   exit       - Done, exit the program.
>   config     - Show system configuration of UPS devices.
>   newconfig  - Change to a new UPS Monitor config file.
>   start      - Start the System UPS Monitor process.
>   stop       - Stop  the System UPS Monitor process.
>   restart    - Restart (stop, then start) the UPS Monitor process.
>   resetpfail - Reset (clear) UPS Monitor's information about the
>                most recent execution of the "powerfail command file".
>   status     - Show System UPS Monitor process status.
>
>------------------------------------------------------------------------------
>
>UPSUTIL: Command > status
>------------------------------------------------------------------------------
>Begin display of UPS Monitor status.
>
>UPS MONITOR PROCESS STATUS:
>
>UPS Monitor Operating State : Running            (PIN =   68)
>UPS Monitor Version Number  :   9                 1 UPS Device  Configured
>System Power State          : Power is normal.    1 UPS Device  Monitored
>Powerfail Recovery Messages : All terminals.      1 UPS Device  Allocated
>Configuration File Name     : UPSCNFIG.PUB.SYS   ( Config File Ok )
>Powerfail Command File Name : $null              ( Pfail Cmd File Ok )
>Powerfail Command File Parms: none
>Powerfail Grace Period (secs:    0
>Powerfail Grace Timer       : Not Running.
>Powerfail Command File      : Not Running.
>Action on UPS Low Battery   : System Abort
>
>UPS DEVICES STATUS:
>
>UPS# Ldev#  Alloc Init    State     Power   Hardware Status
>~~~~ ~~~~~~ ~~~~~ ~~~~ ~~~~~~~~~~~~ ~~~~~~  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
>   1    22   Yes    No  Down/Broken  ???     ???  <---- I think this 
> indicates a problem
>
>End display of UPS Monitor status.
>------------------------------------------------------------------------------
>
>UPSUTIL: Command > exit
>------------------------------------------------------------------------------
>END OF PROGRAM
>PUB:sysgen
>SYSGEN version E.05.00 : catalog version E.05.00    FRI, MAR 21, 
>2008,  4:44 PM
>Copyright 1987 Hewlett-Packard Co. All Rights Reserved.
>
>         **note** Retrieving NMMGR configuration data...
>
>
>         ** First level command **
>
>         io                log (lo)       misc (mi)        spu (sp)
>         sysfile (sy)
>
>         basegroup (ba)    keep(ke)       permyes (pe)     show (sh)
>         tape (ta)
>
>         clear (cl)(c)     exit (ex)(e)   help (he)(h)     oclose (oc)
>         redo
>  sysgen> io
>
>         ** IO configurator commands **
>
>         aclass (ac)      adev (ad)       apath (ap)      avol (av)
>         dclass (dc)      ddev (dd)       dpath (dp)      dvol (dv)
>         lclass (lc)      ldev (ld)       lpath (lp)      lvol (lv)
>         maddress(ma)     mclass (mc)     mdev (md)       mpath (mp)
>         mvol (mv)        hautil (ha)
>
>         clear (cl)(c)    exit (ex)(e)    help (he)(h)    hold (ho)
>         oclose (oc)      redo
>      io> ld 22
>  LDEV:    22  DEVNAME:                    OUTDEV:       22   MODE: 
> JAID
>    ID: 
> HPUPS                              RSIZE:        40   DEVTYPE: TERM
>  PATH: 
> 0/0/4/1.2                          MPETYPE:      16   MPESUBTYPE:  0
>CLASS: 
>HPUPSDEV
> 
>
>      io> exit
>  sysgen> exit
>PUB:showdev 22
>  LDEV     AVAIL         OWNERSHIP         VOLID         DEN   ASSOCIATION
>
>    22   A UNAVAIL       SYS #1  <----- I think also indicates a problem
>PUB:

In addition to configuring ldev 22 via SYSGEN, it is also configured 
via NMMGR DTC path (speed 1200 baud).

Could the problem be related to the fact that it's configured both 
via SYSGEN and NMMGR?

Or what?

Thanks for any help.




-------------------------------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000     Fax: 905.889.3001
email:  [log in to unmask]  web: http://www.gsainc.com
-------------------------------------------------------------------------------------------------


* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2