Subject: | |
From: | |
Reply To: | |
Date: | Mon, 9 Jul 2007 08:32:37 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
We have an unhappy 3000/A500/200-20 this morning. One of the mirrors has split/disabled, but the problem seems to go deeper:
> (MANAGER.SYS)# dstat all
> LDEV-TYPE STATUS VOLUME VOLUME SET - GEN
> ---------- ------- ----------------------------------
> 1-ST336753LC MASTER MEMBER1 MPEXL_SYSTEM_VOLUME_SET-0
> 2-ST336753LC MEMBER MEMBER2 MPEXL_SYSTEM_VOLUME_SET-0
> 30-MAS3367NC MASTER-MD MEMBER1 PRODUCTION-0
> 31-MAS3367NC MEMBER-MD MEMBER2 PRODUCTION-0
> 32-MAS3367NC MASTER-MD MEMBER1 DEVELOPMENT-0
> 33-MAS3367NC MEMBER-MD MEMBER2 DEVELOPMENT-0
> 34-MAS3367NC MASTER-MD MEMBER1 WORKSPACE-0
> 8:28/22/MIRRORED VOLUME DISABLED ON LDEV #44
> 40- BUSY MASTER-MD MEMBER1 PRODUCTION-0
> 41- BUSY MEMBER-MD MEMBER2 PRODUCTION-0
> 42- BUSY MASTER-MD MEMBER1 DEVELOPMENT-0
> 43- BUSY MEMBER-MD MEMBER2 DEVELOPMENT-0
> 44-MAS3367NC *DISABLED-MD MEMBER1 WORKSPACE-0
The 3x drives are master members of mirror pairs and the 4x drives should be the mirrors themselves.
44 has clearly split from the mirror, but what's with the "BUSY" state of the other volumes?
Is this a channel problem? (3x drives are on a separate channel from the 4x drives).
Not sure how to proceed from here (never seen a "BUSY" state from DSTAT).
Ideas? Clues? Condolences? :-)
Jeff
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|