Thanks! I will try auto-negotiate tonight. If it is still
at half-duplex, at least both sides of the connection
will probably at least be in agreement.
Tom
Jeff Kell wrote:
> Tom Hula wrote:
>> The switch still thinks the
>> connection is Half, even with recycling the power and changing
>> ports on the switch. I'm not sure what the problem is...or if there
>> is a problem, but again, thank you all.
> Short answer...
>
> * turn off negotiation at the switch and hard code it at 100/full, *or*
> * turn ON negotiation at the 3000
>
> Longer answer...
>
> Older hardware and negotiation schemes were somewhat optimistic.
> Autonegotiation is supposed to work according to a standard
> (eventually 802.3u clause 28, later extended in 802.3ab) where there
> is an actual exchange of data between both ends of the connection. If
> both ends don't fully support autonegotiation, some implementations
> would be "optimistic" and try to detect the link characteristics on
> their own to try to provide full-duplex if it appears to be allowed.
> Most current schemes are instead pessimistic and will "fall back" to
> half-duplex when in doubt (which is according to standard). So a
> "standard" device set for autonegotiation will only speak full-duplex
> if both ends establish mutually agreeable autonegotiation.
>
> Jeff
>