Andreas

I have bad news and bad news.

The bad news is that there is a corrupt file on the ldev you are trying to
reestablish 
the mirror to.

The other bad news is that to correct it you have to replace the one working
drive with
a new drive.

We had this problem on one of our systems. We backed up the volume set, with
directory,
replaced the drive giving us the error (in your case, 94), deleted and
scratched the volume
set, and rebuild the drive. Did the restore with only the directory option
first, then did
the file restores. The good news is we only lost 1 file, the one that is
giving you the error,
and we could recover it from a prior backup.

I hope this helps.

Robert Schlosser
Global Business Systems
Premier Farnell plc
T 864 487-1362
F 864.487.1904
E [log in to unmask]
> Your #1 source for RoHS compliant products & information.
www.newarkinone.com



-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]]On
Behalf Of Andreas Schmidt
Sent: Thursday, April 19, 2007 10:54 AM
To: [log in to unmask]
Subject: [HP3000-L] MirroredDisk/iX error message ... not found in any
support material!


Folks,

after a disk failure and the command
      REPLACEMIRRVOL set:vol LDEV
in MIRVUTIL we got immediately an open reply:
ACKNOWLEDGE READ ERROR ON MIRRORED REPAIR SOURCE LDEV #94 (Y/N)?
The faulty (but replaced) disk gets the status DISABLED but the other disk
got REPAIR-ERR - a status which cannot be found in any manual/support
documentation available.

The system is still running fine - so far, no problems in the application
and databases detected.

Any idea?

We plan to perform a FSCHECK for the affected volume set tonight ... we
definitely want to have a mirrored system back without a reload of the
affected volume-set.
Any hint is appreciated!

Best regards,
Andreas Schmidt
CSC
Global Infrastructure Services
Managed Computing Services
DuPont-Strasse 1, Room 1-346
D-61352 Bad Homburg
Germany
Phone: +49 (0) 6172 / 87-2117 Fax -2199
eMail: [log in to unmask]

CSC Deutschland Services GmbH
Abraham-Lincoln-Park 1
65189 Wiesbaden
Germany

Board of Directors:
Martin Baumann (chairman),
Werner Martin Deda, Peter Schmidt
Registered Office Wiesbaden, HRB 7574

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *


https://www.mailcontrol.com/sr/wQw0zmjPoHdJTZGyOCrrhg==
IiITKa6RGFnw4813QfZPlxCKV9iZQqzA9hj6iEC+Q==  
Click on the link above to report this email as spam to BlackSpider.

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2