Gordon Montgomery <[log in to unmask]>
Reply To:
Gordon Montgomery <[log in to unmask]>
Date:
Wed, 11 Apr 2007 12:52:10 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (72 lines)
Rich,

Thanks for your suggestion, however it appears that HPCICOMMAND functions
identically to COMMAND. 

Thanks,

Gordon

----- Original Message ----- 
From: "Rich Trapp" <[log in to unmask]>
To: "Gordon Montgomery" <[log in to unmask]>; <[log in to unmask]>
Sent: Wednesday, April 11, 2007 12:44 PM
Subject: RE: Calling Intrinsic Command from Cobol


Gordon,
 I think if you replace the calls to "COMMAND" to "HPCICOMMAND" (with
the appropriate parameter changes) it will function as you desire.

RAT

Rich Trapp | Solutions Architect | Managed Business Solutions (MBS)
(970) 494-4980 | Fax: (970) 416-1543 | Toll free: 800-421-1016 | 1201
Oakridge Dr. Suite 301 | Fort Collins, CO 80525-5562 |
[log in to unmask]  | www.mbshome.com
 

 
CONFIDENTIALITY NOTICE - The information in this email and subsequent
attachments is intended solely for the person or entity to which it is
addressed and may contain confidential and/or privileged information.
Any review, dissemination, copying, printing or other use of this e-mail
by persons or entities other than the addressee is prohibited. If you
have received this e-mail in error, please contact the sender
immediately and delete the material from your computer. 
 
 

-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
Behalf Of Gordon Montgomery
Sent: Wednesday, April 11, 2007 12:06 PM
To: [log in to unmask]
Subject: Calling Intrinsic Command from Cobol

Is there a way to specify the HPPath variable to be used when you use
Call Intrinsic "COMMAND" from within cobol? When the session
logs on, a logon UDC is run that sets the HPPATH variable. We use menu
programs to only offer the users access to the few real
programs they need, and call the programs with the intrinsic call. The
call fails, but if you type the name at the command prompt,
it works.  I know that we can specify the full path in the call, but we
were hoping for a quick and easy solution rather than having
to find and replace all the calls with the full path. Now that I see
this in writing, I can see that either way we will have to
recompile all the menu programs, but I will still ask the question just
for kicks.

Thanks,

Gordon Montgomery
Living Scriptures, Inc.
(801) 627-2000
[log in to unmask]

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2