Stefan:

It depends on if either the cobol or powerhouse traps the error and 
completes normally or if the program abort or abends.

If the program aborts or abends, the job will flush and the job with not 
be streamed.

If on the other hand the programs do not abort or abend, you will need 
to check the JCW value to determine how the program ended and take the 
necessary actions to prevent the job from streaming using the 
"if...then...else".

Olav.



Stefan Thibeault wrote:

>Hello,
>
>I have a job that will run multiple Cobol and Powerhouse programs
>and the last step streams another job. I only want the job to be
>streamed
>if none of the Cobol and Powerhouse programs ended in error. Is there a
>
>variable that I can check to see if all the previous steps were ok
>before
>streaming the job?  Thanks,
>
>
>Stefan
>