Subject: | |
From: | |
Reply To: | Bob J. |
Date: | Thu, 22 Dec 2005 19:47:58 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
That's "processor module number eight", not "the eighth cpu".
The net sum of all of those messages is "system down".
See ITRC for document MSDOWKBRC00015690
Bob J. -- Ideal Computer Services
http://www.icsgroup.net
Craig Lalley wrote:
>
>
> "Bob J." <[log in to unmask]> wrote:
>
> DEAD = system shutdown, forced shutdown, OS has stopped (no kidding?)
> B807 = OS fault, processor module 8, halt 7
> 0105 = continuation message 1, the breaker handler to remote data
> base was re-entered, OS module=genesis
> 020B = continuation message 2, the breaker handler to remote data
> base was re-entered, OS module=genesis
>
> I am confused? Procesor module 8? There are 4 CPU's in this 979 so
> what is "Processor module 8?
>
> TIA,
> -Craig
>
> __________________________________________________
> Do You Yahoo!?
> Tired of spam? Yahoo! Mail has the best spam protection around
> http://mail.yahoo.com
>