Subject: | |
From: | |
Reply To: | |
Date: | Sat, 4 Jun 2005 19:08:18 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I am not familiar with the specific disk array you are using, but I am
running systems with the 12H(older) and the 7110(newer)disc arrays. I use
autoraid configuration with LDEV1 and others configured on the array. I
have lost drives and not had any loss of data. Originally, on the 12H, when
that system had only 5 drives, I lost a drive, and the system became very
slow. It was our production system at that time. Though there was no data
loss, the performance suffered due to 20% disc I/O capacity loss. When I
installed the replacement systems with the 7110s, I filled the array to
capacity. Though it is much more disc than I really need, I get the I/O
throughput I require. I hope this helps.
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|