Johnson, Tracy wrote:
>For some reason, Equater help no longer appears
>and I get blank screens.
>
>
You can get a new copy at the link below.
Mike
http://www.aics-research.com/equater.html
Downloading Instructions
Although downloading /Equater!/ is quite simple, you may wish to print
these instructions before proceeding. The procedure outlined below
requires the use of: (i) a relatively recent version of the /Reflection/
terminal emulator and (ii) either Netscape /Navigator/ 3.0 (or greater)
or Microsoft /Internet Explorer/ 3.0 (or greater), running on any
version of Windows (3.x, 95, or NT). If you're missing any of these
pieces, the downloading procedure unfortunately will not work.
*Step 1.*
Click on the download link above. Store the self-extracting file
(/equater.exe/) anywhere you wish on your PC. Its residency on your
PC will only be temporary. At the conclusion of the downloading
process, after /Equater!/ has been successfully transfered to your
HP3000, this file will be deleted.
*Step 2.*
Once the file has been downloaded, double click on the newly
downloaded file. When you press the UnZip button, the file will
unzip itself and automatically build an /AICS/ directory (folder) on
the C: drive, with a subdirectory (subfolder) labeled /Equater/.
*Step 3.*
You will now find six files in the /Equater/ subdirectory. The six
files are the /Equater!/ calculator and its attendant on-line
manuals, help files, and UDC file. These files are stored in
/Reflection/'s WRQ protocol (LABEL mode) and must be transferred
back onto your HP3000 in that format. The particular version of
/Reflection/ that was used to originally upload these six files was
5.10. It would probably be best to use a reasonably similar version.
*Step 4.*
Using /Reflection/, sign onto your HP3000 as MANAGER.SYS. Please
type /(typing each separate command as one long line; no carriage
returns)/:
*:NEWGROUP AICS;
ACCESS=(R,X:ANY;W,A,L:AC);
CAP=IA,BA,PH
*
*:CHGROUP AICS*
*Step 5.*
Using /Reflection/, transfer the six files, using LABEL mode
transfer, into the AICS group of the SYS account.
*Step 6.*
Once the transfer is complete, please type:
* :SETCATALOG EQUDC.AICS.SYS;
SYSTEM;APPEND *
*:RELEASE EQUDC.AICS.SYS*
The UDCs *:EQ, :EQF, :EQS, :EQX, :EQP* will now activate /Equater/
from every account. This procedure will work without disturbing any
user. System-wide UDCs can be added at any time. The UDCs do not
take effect, however, until the user signs on again and
re-establishes his or her UDC set. The first UDC (*:EQ*) activates
/Equater!/ normally. The others skip the initial screens and jump
directly to the financial, statistical, scientific, and programmer's
calculators, respectively.
*Step 7.*
Test your newly downloaded version of /Equater!/ by signing on to
any account and typing any one of the UDCs we just added in the
previous step.
*Step 8.*
Once you are satisfied that /Equater!/ is indeed working, you may
leave /Reflection/ and delete the self-extracting downloader file
(/equater.exe/) as well as the /Equater!/ subdirectory and its six
files from your PC's file directory.
*Step 9.*
Congratulations on a successful download. We sincerely hope you
enjoy your new copy of /Equater!/.
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|