HP3000-L Archives

February 2005, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Johnson, Tracy" <[log in to unmask]>
Reply To:
Johnson, Tracy
Date:
Thu, 24 Feb 2005 13:06:12 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (61 lines)
Send a PING and an FTP in a job with 60 second pause?

Not really a Ping o'Death but a Ping o'Life?

----

!JOB PINGLIFE,MANAGER.SYS;OUTCLASS=,1;HIPRI;PRI=BS
!RUN PING.NET
172.16.35.19
6
64

!FTP nnn.nnn.nnn.nnn
U MANAGER.SYS
userpass,acctpass
EXIT
!STREAM PING.JOB;IN=,,5
!SET STDLIST = DELETE
!EOJ

----

Actually I use this to "keep" a box alive behind a firewall.  For some reason our box gets dropped from NAT access through the router (times out.)  Also mysteriously, if one Telnets or FTP's from inside the firewall, it wakes it up to the outside world.

BT


Tracy Johnson
MSI Schaevitz Sensors 

> -----Original Message-----
> From: HP-3000 Systems Discussion [mailto:[log in to unmask]]On
> Behalf Of Robert Mills
> Sent: Thursday, February 24, 2005 12:47 PM
> To: [log in to unmask]
> Subject: [HP3000-L] Is the secondary box alive?
> 
> 
> I want to get our primary box to check, on a regular basis, 
> if the secondary box is still alive and working.
> 
> The primary box has MPEX (was thinking of using a %BACKG task 
> to do this).
> Both boxes are running 6.5 and are connected via NS.
> 
> Any suggestions on the least intrusive method?
> 
> regards,
>  
> Robert W.Mills
> Systems Development Manager
> Windsong Services
> (020) 8309 3604
> 
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> 

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2