Hi,
I can't find the bit in the documentation which explains what I'm
seeing. I'm sure it's in there as the VPLUS documentation from HP seems
to be excellent!
I have a required field in my form. I use VSETERROR on it so that it's
highlighted. I call VREADFIELDS and then VFIELDEDITS and check the
numerrs in the com area.
If I press ENTER then numerrs is set. If I press a function key,
numerrs isn't.
I can only guess that VFIELDEDITS isn't ran if a function key is
pressed? But I'm not sure about that as numerrs is set if I don't have
the VSETERROR.
I know there's something about not incrementing numerrs if the field is
already in error which would explain why it doesn't error when F2 is hit
but why does it error when I hit enter?
Thanks.
Peter
--
http://www.beluga.freeserve.co.uk
* To join/leave the list, search archives, change list settings, *