Hi HP3000-L list,
I downloaded patch OSPMX58A and its patch dependencies for MPE/iX 7.0 from
the it resource center
and installed it with Patch/iX. I updated the system from the CSLT tape and
started the second
phase of Patch/iX. Patch/iX then streams 3 installation jobs, but I
encounter a problem with the
installation of patch ODIMXQ2C. The following message is displayed on the
console:
*********************************************
* STMXL.DIAG.SYS library is in use. *
* Critical diagnostics files will not be *
* able to be replaced if they are in use. *
* ODIMXQ2 C is unable to continue. *
*********************************************
I check who is accessing the STMXL file :
:listf stmxl.diag.sys,9
********************
FILE: STMXL.DIAG.SYS
1 Accessor(O:1,P:1,L:0,W:0,R:1),Share
system MANAGER.SYS P:1,L:0,W:1,R:1 LDEV:
#P52 (/usr/sbin/stm/uut/bin/sys/diagmond)
ACCESS: R,X,L-gmulti REC#: 0 FNUM: 22
LOCKS: none
I try to stop the diagmond process by executing STMSHUT.DIAG.SYS,
but the diagmond process keeps on running. I then try to kill the
process with the ABORTPROC command, but then my session is aborted.
Is there any other way of killing the diagmond process?
Regards,
Pascal Luyckx