Denis St-Amand <[log in to unmask]>
Reply To:
Denis St-Amand <[log in to unmask]>
Date:
Wed, 25 Aug 2004 11:02:44 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
 "Cathlene Mc Rae" <[log in to unmask]> wrote in message
news:w-mdnb2BnNFyLbHcRVn-gw@fidnet.com...

...

> 1024 is the 6.0 limit and 2851 is the 7.0 limit. If the message
> "MAXIMUM USER COUNT PER LOGGING PROCESS REACHED".  The currently
> configured value must be increased.  To modify the current value
> SYSGEN must be used.  A start norecovery is then needed to update
> the current value.
>
> Did you do a start norecovery after changing the sysgen value?
> I would recommed a shutdown then a start norecover just to be sure.
>

To this, I add:

Do not forget to create a new SLT to save those configuration changes in
case you'd need to INSTALL in future...

Denis St-Amand