Subject: | |
From: | |
Reply To: | S, Satheesh |
Date: | Thu, 22 Apr 2004 10:57:19 +0530 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi Johan
Thanks a lot for your suggestions. We missed to add PH capability to the program.
We added the PH capability and now it is working fine.
Once again, Thanks a lot.
Best Regards
Satheesh.
-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Wednesday, April 21, 2004 7:36 PM
To: [log in to unmask]; [log in to unmask]
Subject: Re: [HP3000-L] Information on MPE intrisic "CREATE" Condition
Codes
Hello
Under some circumstances the PIN parameter is not updated when
the CREATE intrinsic fails (and returns CCL). The most popular one
is calling CREATE from a program without PH capability, but there
are some others. (refer to the MPE/iX Intrinsic Reference Manual)
I presume the PIN variable already had a value of -1234 before calling
CREATE.
HTH
Johan
----- Original Message -----
From: "Satheesh Kumar" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, 21 April, 2004 12:52
Subject: [HP3000-L] Information on MPE intrisic "CREATE" Condition Codes
> We are facing a problem while executing CREATE intrinsic.
>
> The CREATE intrinsic always returns a Condtion Code value less than ZERO.
> We are getting the PIN value of the created process as -1234.
>
> Our question is why the Condition Code is always giving a value less than
> zero even a process is created with a PIN value -1234.
>
> Normally if the procees is not created the PIN value should be ZERO.
>
> Here process is created but Condition Code is not equal to zero.
>
> Do we have to set up any special enviroment variables to make CREATE
> intrinsic work ?
>
> Please help us in this issue.
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>