Hello
Under some circumstances the PIN parameter is not updated when
the CREATE intrinsic fails (and returns CCL). The most popular one
is calling CREATE from a program without PH capability, but there
are some others. (refer to the MPE/iX Intrinsic Reference Manual)
I presume the PIN variable already had a value of -1234 before calling
CREATE.
HTH
Johan
----- Original Message -----
From: "Satheesh Kumar" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, 21 April, 2004 12:52
Subject: [HP3000-L] Information on MPE intrisic "CREATE" Condition Codes
> We are facing a problem while executing CREATE intrinsic.
>
> The CREATE intrinsic always returns a Condtion Code value less than ZERO.
> We are getting the PIN value of the created process as -1234.
>
> Our question is why the Condition Code is always giving a value less than
> zero even a process is created with a PIN value -1234.
>
> Normally if the procees is not created the PIN value should be ZERO.
>
> Here process is created but Condition Code is not equal to zero.
>
> Do we have to set up any special enviroment variables to make CREATE
> intrinsic work ?
>