Subject: | |
From: | |
Reply To: | |
Date: | Fri, 26 Jul 2002 09:57:00 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Re:
>
> Reconfigure the serial port as term type 18 if it isn't already. Simpler=
> is=20
> sometimes better.
I have to disagree here. The most likely culprit for the original problem is a
bad serial cable. The spooler is sending a status request to the printer
(<ESC>?) and expecting a ACK (CTRL-F) as a reply. When the ACK is not received
it dumps out the cryptic messages on the console that were detailed in the
original post and stops the spooler. This is a design feature to prevent lost
data.
Printer type 18 is XON/XOFF protocol with no status checking. The spooler
simply sends data until it receives an XOFF. If there indeed is a broken wire
or connector, somebody tripped over the wire and ripped it out of the back of
the printer, or even if the printer is simply powered off, reports will go
directly to the bit bucket. Why? Because you have a one-way conversation.
Sometimes the problem is just with the wire or pin that transmits data back to
the system. In that case the printer will receive data but cannot respond with
an ACK (type 22) or an XOFF (type 18 and 22). Setting the printer to 18 will
most likely mask the real problem or make it worse with reports that disappear
or printouts with missing data in the middle.
The prudent thing to do is determine the root cause of the problem and not
just blindly reconfigure the system.
Doug.
Doug Werth Beechglen Development Inc.
[log in to unmask] Cincinnati, Ohio
* To join/leave the list, search archives, change list settings, *