AUTOPAT used to add the entries in HPSWINFO as well.
If they are missing then probably because
* the patch is only written to be applied using PatchIX,
* the patch failed
* the HPSWINFO file couldn't be expanded during the process for any reason
Best regards, Andreas Schmidt, CSC, Germany
John Burke <[log in to unmask]>@RAVEN.UTC.EDU> on 20/03/2002 01:24:56
Please respond to John Burke <[log in to unmask]>
Sent by: HP-3000 Systems Discussion <[log in to unmask]>
To: [log in to unmask]
cc:
Subject: Re: [HP3000-L] patched or not??
Autopat? Tsk, tsk. Should have used patchix! In which case it will update
hpswinfo. It's been so long since I used autopat, I don't recall if it
updates hpswinfo.
As for psswinvp, the command file in 6.5 is broken, the correct calling
sequence is:
[3]:type psirpt.pred.sys
file psilist=$stdlist
run psswinvp.pred.sys;xl='xl.pred.sys,diagxl.pred.sys'
John
> From: Donna Garverick [mailto:[log in to unmask]]
>
> so we're applying post-6.5pp3 reactive patches using
> autopat....and we think (but are really wondering....) that
> we're done. if we look in hpswinfo, the last entry is for
> pp3 -- not the reactives. in patchxl, i find a file
> 'logok'....and the top of it is:
>
> :print logok.patchxl
> AUTOPAT - Patches below installed by xxxxx THU, MAR 14,
> 2002 3:42 PM
> Patch ID SR Number - Module Identity
> Timestamp
> ======== =========== =============================
> =========
>
> shouldn't have something been added to hpswinfo by autopat?
> is there a step waiting to be done? (and no, i didn't do
> this....else i wouldn't be asking) - d
>
> btw -- psswinvp.pred appears to be non-functioning (won't
> say 'broke'....won't tell you what i'm thinking on that
> topic either :-)
>