Subject: | |
From: | |
Reply To: | |
Date: | Mon, 18 Mar 2002 13:10:56 -0800 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Re:
> I have Relate/3000 working on MPE/IX 7.0
> I don't know how many people are still using Relate/3000. We
> still have a couple applications and have had to patch the executable
...
> The only error is when using BUILDER or any HLI program starting Relate.
> In other words Relate itself runs to run fine on 7.0, just
> Builder doesn't work. The patch takes care of all the problems I have found.
>
> I would be happy to fax anyone a copy of what I did.
Great!
BTW, that patch will probably not work on 7.0 PP1 and later, if you have
BIGPINs enabled on your system (e.g., more than 8191 PINs),
because then the PIN of your parent process is stored in the PCB,
instead of the current PCB offset of the parent process being
stored there.
Stan Sieler [log in to unmask]
www.allegro.com/sieler/wanted/index.html www.allegro.com/sieler
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|