Tracy;
No TEMP files found. :-(
Don Harrington
Sr. Systems Analyst
Facilities Applications Support
Shared Services Group
The Boeing Company
P.O. Box 3707 M/C 6C-AK
Seattle, WA 98124-2207
(v) 425-234-1145 (f) 425-234-0464 (p) 206-797-6360
The opinions expressed in this e-mail reflect those of the sender. They do
not necessarily reflect the opinions of The Boeing Company unless
specifically stated otherwise.
-----Original Message-----
From: Tracy Pierce [mailto:[log in to unmask]]
Sent: Friday, January 25, 2002 10:13 AM
To: 'Harrington, Don'
Subject: RE: FORTRAN 77 OPEN/CLOSE Issue
yes, I got that. when you run the program, are you left with a temp file
FTN03? that would indicate that your file equation is having no effect.
> -----Original Message-----
> From: Harrington, Don [mailto:[log in to unmask]]
> Sent: Friday, January 25, 2002 10:13 AM
> To: Tracy Pierce
> Subject: RE: FORTRAN 77 OPEN/CLOSE Issue
>
>
> Tracy;
>
> Maybe; but I think that the '3' in the OPEN already equates
> to 'FTN03' in
> the file equation.
>
> Later,
> Don Harrington
> Sr. Systems Analyst
> Facilities Applications Support
> Shared Services Group
> The Boeing Company
> P.O. Box 3707 M/C 6C-AK
> Seattle, WA 98124-2207
> (v) 425-234-1145 (f) 425-234-0464 (p) 206-797-6360
>
> The opinions expressed in this e-mail reflect those of the
> sender. They do
> not necessarily reflect the opinions of The Boeing Company unless
> specifically stated otherwise.
>
>
>
> -----Original Message-----
> From: Tracy Pierce [mailto:[log in to unmask]]
> Sent: Friday, January 25, 2002 10:09 AM
> To: 'Harrington, Don'
> Cc: HP3000-L (E-mail)
> Subject: RE: FORTRAN 77 OPEN/CLOSE Issue
>
>
> well, you got what you paid for, sorry. ;-) I'm still no
> fortran geek, but
>
> I notice that some of your input files are qualified a bit,
> and wonder if
> maybe you need to do this for your spoofles. Are you getting
> temp files
> called FTN03 etc? Could be your file equations are having no
> effect, which
> could be why FTN01 has MPE info attached, rather than tacked on as a
> comment. Why not try qualifying your output files a bit, changing
> > > OPEN (3) ! FAC201D
> to, maybe
> > > OPEN (3,file="*FTN03") ! FAC201D
> or better
> > > OPEN (3,file="*FAC201D") ! FAC201D
> which would require a different file equation but no comment.
>
> Tracy
>
>
>
>
>
>
> either via
> > > !FILE FTN01=HDR,OLD
> > > !FILE FTN02=EDATA1,OLD
> > > !FILE FTN03=FAC201D;DEV=LPS61 ,8,1;CCTL
> > > !FILE FTN07=FAC201K;DEV=LPS61,8,1;CCTL
> > > !FILE FTN08=SUSP201F,OLD
> > > !FILE FTN10=FAC201S;DEV=LPS61 ,8,1;CCTL
> > > !FILE FTN13=TEMP13,NEW;TEMP;REC=-30,,F,ASCII;DISC=500
> > > !FILE FTN14=TEMP14,NEW;TEMP;REC=-30,,F,ASCII;DISC=500
> > > !FILE FTN15=FAC201F;DEV=LPS61 ,8,1;CCTL
> > > !FILE FTN16=FAC201E;DEV=LPS61 ,8,1;CCTL
> > > !FILE FTN17=FAC201R;DEV=LPS61 ,8,1;CCTL
> > > !FILE FTN18=FAC201P;DEV=LPS61 ,8,1;CCTL
> > >
> > > The OPENs look like this:
> > >
> > > OPEN (1,FILE="HDR",STATUS="OLD")
> > > OPEN (2,FILE="EDATA1",STATUS="OLD")
> > > OPEN (3) ! FAC201D
> > > OPEN (7) ! FAC201K
> > > OPEN (8,FILE="SUSP201F",STATUS="OLD")
> > > OPEN (10) ! FAC201S
> > > OPEN (11,FILE="DELENG1",STATUS="OLD")
> > > OPEN (12) ! FAC201A
> > > OPEN (13) ! TEMP SORT FILE
> > > OPEN (14) ! SORT OUTPUT FILE OF
> > > TEMP FILE
> > > OPEN (15) ! FAC201F
> > > OPEN (16) ! FAC201E
> > > OPEN (17) ! FAC201R
> > > OPEN (18) ! FAC201P
> > >
> > > The CLOSEs look like this:
> > >
> > > CLOSE (1)
> > > CLOSE (2)
> > > CLOSE (3) ! FAC201D
> > > CLOSE (7) ! FAC201K
> > > CLOSE (8)
> > > CLOSE (10) ! FAC201S
> > > CLOSE (11)
> > > CLOSE (12) ! FAC201A
> > > CLOSE (13) ! TEMP SORT FILE
> > > CLOSE (14) ! SORT OUTPUT FILE
> > > OF TEMP FILE
> > > CLOSE (15) ! FAC201F
> > > CLOSE (16) ! FAC201E
> > > CLOSE (17) ! FAC201R
> > > CLOSE (18) ! FAC201P
> > >
> > > My question is: Why don't the output files get generated?
> > >
> > > Thanks,
> > > Don Harrington
> > > Sr. Systems Analyst
> > > Facilities Applications Support
> > > Shared Services Group
> > > The Boeing Company
> > > P.O. Box 3707 M/C 6C-AK
> > > Seattle, WA 98124-2207
> > > (v) 425-234-1145 (f) 425-234-0464 (p) 206-797-6360
> > >
> > > The opinions expressed in this e-mail reflect those of the
> > > sender. They do
> > > not necessarily reflect the opinions of The Boeing Company unless
> > > specifically stated otherwise.
> > >
> > > * To join/leave the list, search archives, change list settings, *
> > > * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> > >
> >