Hi Gilles and Others :)
    Thanks for the good info so far :)   What I am looking at is trying to
create a job stream that is self-contained with the vplus screen based cobol
program getting it's input from within the JCL... and the file redirection
might just do that... so any other ideas/thots on this one?  Gilles' answer
was echo'ed by a few other private replies... for which I thank all :)

Art "hmmm... I wonder.... " Bahrs

----- Original Message -----
From: "Gilles Schipper" <[log in to unmask]>
To: "Art Bahrs" <[log in to unmask]>; <[log in to unmask]>
Sent: Tuesday, October 16, 2001 8:51 AM
Subject: Re: [HP3000-L] VPlus Screen Experts


> Could be simple - or not.
>
> First of all, you cannot have the batch job satisfy the vplus terminal
read
> calls from $stdin - the VOPENTERM will fail.
>
> So, the first requirement is to use a :file command to re-direct the
> terminal I/O.
>
> If you are trying to re-direct VPLUS screen output to a DTC-connected
> terminal, you should be fine.
>
> If that's the case, you need to know what the formal file designator is
for
> the terminal - it's sometimes "A264X", but often not. If you have the
> source, look for the value in the parameter specified for "VOPENTERM". It
> will be equal to the formal file designator you need to use, eg:
>
> :file A264X;dev=nnn
>
> where nnn is the ldev number of the DTC-connected terminal you wish to
use.
>
> If you do not have the source, you should be able to get the formal
> designator name by running the program  and using glance, sos, or other
> such tool.
>
> As far as I know, you cannot redirect VPLUS I/O to a lan-connected
"terminal".
>
>
> At 11:27 AM 2001-10-16, Art Bahrs wrote:
> >Hi All :)
> >    Ok... an On Topic post...
> >
> >    Question: How does one run a VPlus Screen in batch??
> >
> >    I am sure that it is doable... ok... so maybe I am just hoping it is
> >doable! hehehe
> >
> >Art "if it were easy the users would do it! hehe" Bahrs
> >
> >* To join/leave the list, search archives, change list settings, *
> >* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
> --------------------------------------------------------------------------
-
> Gilles Schipper
> GSA Inc.
> HP System Administration Specialists
> 300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
> Voice: 905.889.3000     Fax: 905.889.3001
> Internet:  [log in to unmask]
> --------------------------------------------------------------------------
-
>
>