At 10:52 AM -0800 12/5/00, Donna Garverick wrote:
>kill needs a 'pid' (a process id) to do it's thing.  how do you
>get a pid?  by using ps.  (ohhh, ahhh :-).  the problem is, ps
>(on 6.0) was compiled without 'ba' capability -- makes it kinda
>hard to write a *job* to halt posix jobs....


Why can't you just do

  LinkEd> altprog kill.hpbin.sys;cap=ba,ia,ph

and add BA yourself?

HP may have made the error in not sending you a version of KILL that has
BA, but there's no reason why you can't add it after the fact. (BTW, my
version of KILL on 6.0 PP2 already had BA when I checked, but someone else
here might have added it)



Barry Lake                              [log in to unmask]
Allegro Consultants, Inc.               www.bogus.allegro.com
(408)252-2330
--------
Attempting to reduce spam influx.