HP3000-L Archives

November 2000, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Stan Sieler <[log in to unmask]>
Reply To:
Stan Sieler <[log in to unmask]>
Date:
Wed, 8 Nov 2000 17:22:35 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (20 lines)
Re:
> My One System HP3000/960 was halted on 05th November in Morning for 15
> minutes. The error was
>
>         THE ABOVE SYSTEM HALTED
>         SYSTEM ABORT 1740 FROM SUBSYSTEM 107
>         SECONDARY STATUS : INFO

:debug
= errmsg (#1740, #98)
'FILL_ALLOCATED_SEC_STORAGE - FILL_DISC returned an error.'

(#98 is a "magic number")


Looks like a disk drive problem.

Stan Sieler                                           [log in to unmask]
www.allegro.com/sieler/wanted/index.html          www.allegro.com/sieler

ATOM RSS1 RSS2