HP3000-L Archives

October 2000, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Ronald R Horner <[log in to unmask]>
Reply To:
Ronald R Horner <[log in to unmask]>
Date:
Tue, 10 Oct 2000 08:38:14 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (25 lines)
The MPE setcounter command will do the job.  Just set your limit to the
desired value and the system does the rest.  In your case enter the
following:

setcounter counter=outsp;max=<desired max spool number>;base=1

Later

"Chana, Harpreet TCS1C" wrote:

> Hi All,
>
> Please let me know how I can reset my spoolfile numbers. Right now it is
> o1066970. How I can start it from 1. Without rebooting the System.
>
> With Warm Regards
>
> Harpreet Singh Chana

--
Ron Horner
HP3000 Systems Admin
JC Penney Co., Inc.
(414) 259-2274

ATOM RSS1 RSS2