Bug.
I found SR 8606104044
Variable HPDATE aborts job with CIERR 9805 after MPEKXP4A installed
problem
On MPE/iX 6.0, after MPEKXM0 or MPEKXP4 is installed, an attempt to use
the HPDATE system variable may fail with:
Variable name encountered, but variable is not defined. (CIERR 9805)
fix
Will be fixed in the future release of mPE/iX
Fixed in patch MPEKXW7.
HTH
Thomas Hoffmann wrote:
>
> Hi all,
>
> Every sunday a job does db-maintenance. This job runs for 3 weeks now,
> and we never had a problem...
> until yesterday:
> We are on 6.0 pp1 (979KS/200), and the job has NOT BEEN MODIFIED since
> september 7th.
>
> Sunday 10. september, jobs works fine:
> :JOB XXXXX,........
> <snip>
>
> :IF (HPDATE >= 8 AND HPDATE <= 14)
> *** EXPRESSION TRUE
> :do this, do that
> :ENDIF
>
> ------------------------------------------------------------------------------------------
>
> Sunday 17. september:
> :JOB XXXXX,........
> <snip>
>
> > :IF (HPDATE >= 8 AND HPDATE <= 14)
> > ^
> > Variable name encountered, but variable is not defined.
> > (CIERR 9805)
> > REMAINDER OF JOB FLUSHED.
> > CPU sec. = 631. elapsed min. = 92. SUN, SEP 17, 2000, 5:43 AM.
> >
>
> --------------------------------------------------------------------------------------------
>
> Today I streamed it again, and it worked as expected:
>
> JOB XXXXX,........
> <snip>
>
> > :IF (HPDATE >= 8 AND HPDATE <= 14)
> > *** EXPRESSION FALSE: COMMANDS IGNORED UNTIL MATCHING ELSEIF/ELSE
> > /ENDIF
> > :ECHO ** bla bla bla test test
> > :ENDIF
> >
>
> -------------------------------------------------------------------------------------------------
>
> Is this a bug or a feature? :-)
>
> Any ideas?
> Thank you
>
> Thomas Hoffmann
> HR Mathieu Software AG
|
|
|