Subject: | |
From: | |
Reply To: | |
Date: | Thu, 3 Aug 2000 16:03:44 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Examine is an extension of HP for compatibility. See:
http://www.docs.hp.com/cgi-bin/doc3k/B3150090013.11820/84
Instead, you should use the Inspect statement. See:
http://www.docs.hp.com/cgi-bin/doc3k/B3150090013.11820/92
Michael B Sullivan Computer Services Team
College of the Mainland Systems Analyst
1200 Amburn Rd Room TVB-304
Texas City, TX 77591-2499 (409) 938-1211 x302
>>> "Chipurnoi, Scott (SSC)" <[log in to unmask]> 8/3/2000 3:34:41 PM >>>
I am posting this to the list as I was unable to help a friend resolve a
Cobol compile problem. He is converting some programs from HP3000's Cobol
to MicroFocus Cobol for use on the 9000. He is getting the following
compile error.
* Compiling cyb99gls.cob
204 EXAMINE DEBIT-AMT REPLACING ALL ' ' BY '0'.
* 9-S***********
**
** '.' missing
* Total Messages: 1
* Unrecoverable : 0 Severe : 1
* Errors : 0 Warnings: 0
* Informational : 0 Flags : 0
* Data: 1568 Code: 1143
cob: error(s) in compilation: cyb99gls.cob
Compile Not Sucessful for cyb99gls.cob
The portion of code that is not compiling is:
050000 ACCUM-TOTALS.
RS980213
050005 IF DEBIT-AMT = SPACES
RS980213
050010 GO TO ACCUM-CR.
RS980213
050015 EXAMINE DEBIT-AMT REPLACING ALL ' ' BY '0'.
050020 MOVE DR-DOLLARS TO WK-DOLLARS.
RS980213
050025 MOVE DR-CENTS TO WK-CENTS.
RS980213
050030 ADD WK-AMOUNT-9 TO TOT-DR.
RS980213
The compile says it is failing due to a '.' missing, but it looks like it is
there at the end of the "EXAMINE" statement in the code.
Having never used MicroFocus, I don't know if there are problems, to tell
him about, in going from HP's Cobol to Microfocus.
Has anyone come across something like this?