HP3000-L Archives

March 2000, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Tom Hula <[log in to unmask]>
Reply To:
Date:
Fri, 24 Mar 2000 10:54:53 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (35 lines)
I had to reconfigure device 21 to do 19200 baud rate and found out that I also
had to do a Ctrl-B at the console and there is a command (do a help) to
configure the remote console modem.  Seems like I had a quiet system at the
time, but don't recall if that and a reboot was required or not.

Jeff Baranda wrote:

> Hello, I am trying to install "Nightwatch", a failsafe notification box on
> our HP system using DEV 21. I need to first configure DEV 21 as follows.
>
> Term type = 10
> Line speed = 9600
> Record width = 80
> Modem type = 1
> Modem behavior = 1
> Parity = None
> Speed/parity sensing = N
> Hardware Shaking = N
> Allow Hello = Y
> NL10 Device = N
>
> I tried NMMGR but I do not see where I can set all of these options unless
> it is a profile for my DTC ports.
>
> Thanx in advance.
>
> Jeff Baranda
> FAA Western Federal CU

--

        Tom Hula
        Victor S. Barnes Company
        616.361.7351  x173

ATOM RSS1 RSS2