Just a note
In DBUTIL >DETACH IMAGE-BASE does not delete DBEs it just detaches them from
the database.  Also you can try IMAGESQL SET TURBODB database name then SET
SQLDBE sqldbe name then DETACH

-----Original Message-----
From: OpenMPE Support Group [mailto:[log in to unmask]] On Behalf Of
Emerson, Tom
Sent: Tuesday, September 27, 2005 1:48 PM
To: [log in to unmask]
Subject: Re: Detaching a non-existant DBE -- how?

> -----Original Message-----
> From: Miller,Keven [mailto:[log in to unmask]]
> 
> DBUTIL
>  >DETACH IMAGE-BASE

Bingo!!!

(though it seems like a shotgun approach rather than a sniper approach -- I
gather this will delete ALL the DBE's associated with the database rather
than one specific DBE)

should be easy enough to add to the job ahead of running adager to make the
changes -- fortunately, we already have a specific re-attach script 

Technically, the DBA should have streamed our detach job, THEN this job, and
then the re-attach job.  This *probably* would have worked since this would
have removed the PRODUCTION DBE leaving only one DBE attached to the
database.  though I'm unsure if adager would have choked on the fact the DBE
and/or account doesn't exist, but then, that might have been a good thing if
it failed on the attempt to reconnect -- we would effectively have what we
needed: the removal of the bogus DBE


> Keven
> 
> Emerson, Tom wrote:
> > One of our databases needed a structural change [but]
> >    according to the turboconnect file, your database is attached to
> > 
> >          dbe.sql.testacct
> >          dbe.sql.prodacct

> >  [therefore adager] can only do capacity management and reporting 
> [paraphrased] if the database is attached to more than one DBE
[...]



THIS E-MAIL IS INTENDED ONLY FOR THE ADDRESSEE(S) AND MAY CONTAIN
CONFIDENTIAL INFORMATION.   IF YOU ARE NOT THE INTENDED
 RECIPIENT, YOU ARE HEREBY NOTIFIED THAT ANY USE OF THIS
 INFORMATION OR DISSEMINATION, DISTRIBUTION OR COPYING OF THIS
 E-MAIL IS STRICTLY PROHIBITED.  IF YOU HAVE RECEIVED THIS
 E-MAIL IN ERROR, PLEASE NOTIFY THE SENDER IMMEDIATELY BY RETURN
 E-MAIL AND DELETE THE ORIGINAL MESSAGE.THANK YOU.

ATOM RSS1 RSS2