On 03/18/99 at 05:13:09 PM, Rich Holloway ([log in to unmask]) wrote:

>I would like to know how TurboStore is working with jumbo data sets. We
>keep getting different statements as to who the problem belongs to from
>Roadrunner.

There is a known problem with restoring jumbo datasets after an "online
backup" and the time-stamps for the chunks being "out of sync".  The SR is
SR1653284398.

Adager will automatically correct this condition during the "Consistency Check"
if Adager can get exclusive access to the database.  There is also a JCW
which may bypass the check within DBOPEN depending upon which version of
IMAGE you are on.  The JCW is MFDDEBUG set to a value of 1024.  I'm checking
to see which version of TurboIMAGE this applies to and also if there is a
version of TurboIMAGE which will also re-sync the time-stamps on the DBOPEN.

This is an HP problem and can happen with both RoadRunner and TurboStore and
I'm not sure about Orbit Backup.

Hope this helps,


+---------------+
|               |
|            r  |  Ken                             [log in to unmask]
|          e    |                           http://www.adager.com
|        g      |  Ken Paul                      Tel 208 726-9100
|      a        |  Customer Support              Fax 208 726-2822
|    d          |  Adager Corporation
|  A            |  Sun Valley, Idaho 83353-3000            U.S.A.
|               |
+---------------+