Subject: | |
From: | |
Reply To: | |
Date: | Fri, 13 Jun 2003 15:05:27 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Re:
> smread fail
> 2146926592 -26214215
The second number, when viewed as hex, looks like an HPE_STATUS format
value. If interpreted that way, it's error -#400 in subsystem $b9.
$b9 is 'File System Storage Management'. Unfortunately, error #400/$b9
isn't in the system error catalog.
The first number, when viewed as hex, looks interesting:
:calc 2146926592
2146926592, $7FF78000, %17775700000
$7ff7 is a common value in some MPE structures, meaning "no PIN"
(e.g., a structure that might want to record what PIN owns it would
typically have $7ff7 if it is unowned).
--
Stan Sieler
[log in to unmask]
www.allegro.com/sieler/wanted/index.html
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|