HP3000-L Archives

May 1997, Week 1

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Jeff Vance <[log in to unmask]>
Reply To:
Jeff Vance <[log in to unmask]>
Date:
Wed, 7 May 1997 14:38:12 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (19 lines)
On May 7, 12:18pm, Eric Kundl wrote:
> Subject: Re: Calling HP intrinsic
> Ed,
> At some point in the past, HP enhanced the JCW's so that when you set a
> JCW, a variable is also set with the same name. I believe JCW's are limited
> to numbers but a session variable can also hold strings and booleans. So
> you can get a JCW or a Session Variable with the HPCIGETVAR intrinsic.
...

On MPE XL and iX when a JCW is created via :SETJCW, SETJCW(), PUTJCW()
a CI variable entry is created for the JCW name and value.  A bit is
set indicating that this is a JCW, rather than an integer variable, and
thus is restricted to 16 bit constraints that apply to JCWs.  There is
only a single entry per JCW.

Jeff Vance, CSY

--

ATOM RSS1 RSS2