Glenn A. Mitchell ([log in to unmask]) wrote:
: I am trying to add an additional neighbor gateway on my 947.  When I
: validate the link, I get an error message:
 
: CONFIGURED GATEWAYS(15) MUST BE <= IPU MAX GATES (14).  (VALERR 32)
 
: The (old) error message book I have says delete neighbor gateways to get
: under the IPU MAX.  Is there really a max of 14 neighbor gateways?  My
: Series 70 didn't blink when I added this gateway (both machines have the
: same neighbor gateways).
 
- yes indeed, there is a limit of 14 gateways.  This limit will disappear very
  soon, since the internal part of the code imposing this limit (using CM DSTs)
  has already been written to native mode and is coming out soon (I assume
  in 5.0 and later).   With the native mode IP routing module, the routing will
  become more flexible and limits will 'disappear'.
 
:-) Eero - HP CSY Networking lab.