John Korb writes:
>When I tried to bring up a Micro 3000 system tonight, I received a failure
>message during the self test prior to AUTOWARMSTART (which was not
>performed due to the card failure). The failure message was:
>
> Local Area Network Interface Controller failure 002E
This is a loopback failure; it's normal if you don't have at least an AUI
and 25-ohm termination (two 50-ohm terminators on a tee will do). You can
ignore it if you don't intend to use the system on a network.
-- Bruce
--------------------------------------------------------------------------
Bruce Toback Tel: (602) 996-8601| My candle burns at both ends;
OPT, Inc. (800) 858-4507| It will not last the night;
11801 N. Tatum Blvd. Ste. 142 | But ah, my foes, and oh, my friends -
Phoenix AZ 85028 | It gives a lovely light.
btoback AT optc.com | -- Edna St. Vincent Millay
Mail sent to [log in to unmask] will be inspected for a
fee of US$250. Mailing to said address constitutes agreement to
pay, including collection costs.