Joe Silagi <[log in to unmask]>
Reply To:
Joe Silagi <[log in to unmask]>
Date:
Wed, 10 Feb 1999 07:57:13 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (42 lines)
Hi Claire.

I think the problem is that pclink2 isn’t getting started.  Since you
are in a menu program the host startup sequence (e.g.,  run
pclink2.pub.sys) never makes it to the 3000.  What you will need to do
is intercept the host startup sequence that Reflection sends and start
it from within your menu program. Here is an example:

echo ![chr(27)]&oBsend pcfile to hp3kfile
input mpe_command
!mpe_command
comment  Optionally you can get and test the file transfer completion
code.
input reflect_cc

Hope this helps,

Joe Silagi
WRQ, Inc.


> claire Pope wrote in message ...
> We use Vesoft's security 3000 to create menus for our users so that they
> don't have complete access to commands.  However, some of our users need to
> be able to transfer files back and forth to the HP.  When we try to do this,
> we get a message that says that it isn't connecting to the host.  I've tried
> going into the file transfer setup and putting a colon before the run
> pclink2 command, but it didn't help.  Does anyone have any suggestions on
> how to solve this?
> Thanks in advance for your help!
>
>
>
> Claire Pope
> Mary Washington College
> Fredericksburg, VA  22401
> Email:   [log in to unmask]
> Phone: (540)654-2260
> Fax:      (540)654-1596
>
>