Subject: | |
From: | |
Reply To: | |
Date: | Fri, 14 Nov 1997 22:23:29 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Well, I feel really strange and I may show my ignorance here, but I have to
correct Wirt's response in just a teeny, tiny little bit:
Wirt says:
>Yes. Changes you make in NMMGR aren't transferred to the DTC without doing
a
>shutdown and a start norecovery. As to its importance, it actually matters
a
Maybe prior to MPE/iX 5.5. I'm on 5.5 and I have made numerous changes to
DTC configs in NMMGR, including defining an entirely new DTC. In every
case
I was able to activate the new config by doing a RESET on the DTC in
TERMDSM within SYSDIAG. The reset performs a code download to the DTC (it
also aborts all the other users on that DTC's ports) and thereby activates
the new config.
Jim Phillips Manager of Information Systems
Voice: (330) 527-2124 Therm-O-Link, Inc.
Fax: (330) 527-2123 PO Box 285; 10513 Freedom St.
Email: [log in to unmask] Garrettsville, Ohio 44231
|
|
|