Subject: | |
From: | |
Reply To: | |
Date: | Wed, 6 Oct 1999 09:20:34 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
In order to reset the internal modem, you need a license to run the
consolan diagnostic.
Assuming you have the appropriate password to enable the license, do the
following:
:hello manager.sys
:sysdiag
consolan pdev=10/4/0 section=2(23)
You will be asked to choose which port to reset. Choose the remote port -
not the console port.
The pdev will change according to which model HP3000 you have. 10/4/0
should be the correct path for your 969.
At 09:31 AM 1999-10-06 +0200, Johan BEGHEIN wrote:
>Hello,
>
>I have a 969/200 box, with an internal modem on ldev 21.
>
>Predictive wants to do a call to the support center, but it can't fopen
>ldev21.
>
>Is there a way to do a reset of the ldev21 port, or the modem, without
>bringing down the system.
>
>I already tried with sysdiag/termdsm/reset/ldev, also with Openview DTC
>manager/ ldev reset, but it seems this utilities aren't supported on this
>port.
>
>Ant help would be appreciated.
>
>Thank You.
>
>
---------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP3000 & HP9000 System Administration Specialists
300 John Street, Box 87651 Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000 Fax: 905.889.3001
Internet: [log in to unmask]
---------------------------------------------------------------------------
|
|
|