I can do the streamx command. When I try it, I get the same response.
Tom
From: Tony Summers
Sent: Thursday, June 17, 2010 10:53 AM
To: Tom Hula
Subject: RE: [HP3000-L] VESOFT STREAMX
Is the STREAMX command available to you ? (usually in the same UDC file
- I think this bypasses MPEX and invokes the mpe stream command directly
You would have to create a two-line job to verify...
!JOB test,manager.sys
!EOJ
This will confirm if the problem's caused by something broken at the MPE
layer (e.g. spoolers down ?)
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
Behalf Of Tom Hula
Sent: 17 June 2010 15:49
To: [log in to unmask]
Subject: Re: [HP3000-L] VESOFT STREAMX
HELP STREAM shows me this:
STREAM
ANYPARM ALLPARMS=![""]
COMMENT This UDC implements VESOFT's STREAM command on MPE/iX IF
BOUND(HPPIN) THEN
COMMENT ** Loading UDC parm into variable handles embedded quotes.
COMMENT ** Using HPPIN handles process-handling environments.
ECHO >VE!HPPIN !ALLPARMS
INPUT VE!HPPIN<VE!HPPIN
SETVAR VE!HPPIN LTRIM(VE!HPPIN)
PURGE VE!HPPIN,TEMP>$NULL
IF POS('"', VE!HPPIN)<>0 THEN
IF POS("'", VE!HPPIN)<>0 THEN
SETVAR VESAVEHPMSGFENCE 0
SETVAR HPMSGFENCE 2
SETJCW INSIDEMPEX=0
SETVAR HPMSGFENCE VESAVEHPMSGFENCE
IF INSIDEMPEX=0 THEN
ECHO ERROR: You can't use ' and " quotes together outside of
MPEX.
ELSE
RUN MAIN.PUB.VESOFT;INFO=VE!HPPIN;PARM=%1021
ENDIF
ELSE
XEQ MAIN.PUB.VESOFT;INFO='![VE!HPPIN]';PARM=%1021
ENDIF
ELSE
XEQ MAIN.PUB.VESOFT;INFO="![VE!HPPIN]";PARM=%1021
ENDIF
DELETEVAR VE!HPPIN
ELSE
XEQ MAIN.PUB.VESOFT;INFO='!ALLPARMS';PARM=%1021
ENDIF
Nothing has been changed in system libraries at all.
Tom
From: Tony Summers
Sent: Thursday, June 17, 2010 10:15 AM
To: Tom Hula
Subject: RE: [HP3000-L] VESOFT STREAMX
1) Check the MPE stream command is being diverted to use the special UDC
that VESOFT provide (i.e. HELP STREAM)
2) Has VESOFT being removed from the system libraries ?
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
Behalf Of Tom Hula
Sent: 17 June 2010 15:11
To: http://raven.utc.edu/archives/hp3000-l.html *
<Clip>
The contents of this email are confidential to the intended recipient
and may not be disclosed. Although it is believed that this email and
any attachments are virus free, it is the responsibility of the
recipient to confirm this.
Details of Smith & Williamson group companies and Nexia Smith &
Williamson Audit Limited and their regulators (where applicable), can be
found at this URL
http://www.smith.williamson.co.uk/disclosure
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
The contents of this email are confidential to the intended recipient and may not be disclosed. Although it is believed that this email and any attachments are virus free, it is the responsibility of the recipient to confirm this.
Details of Smith & Williamson group companies and Nexia Smith & Williamson Audit Limited and their regulators (where applicable), can be found at this URL
http://www.smith.williamson.co.uk/disclosure
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|