Simonsen, Larry wrote:
>
> I'm looking for some ideas on keeping the backup stdlist files on
> disc rather than printing them every day/week.
Here's a snippet from a job I wrote to do that very thing...
!JOB SPOOLF,MANAGER.SYS;OUTCLASS=P0,1,1
!
!###########################################################
!# #
!# SPOOLF.STREAM.SYS #
!# #
!# DAILY SPOOLFILE CLEANUP JOB. #
!# #
!###########################################################
!
!ERRCLEAR
!CONTINUE
!
!LISTSPF O@; SELEQ= &
! [(FILEDES=SYSLIST) AND (JOBNAME=PARTBKUP)] > PARTSYS
!
!IF CIERROR = 0
!
! CONTINUE
! PURGE PARTSYS7.SPOOL
! CONTINUE
! RENAME PARTSYS6.SPOOL, PARTSYS7.SPOOL
! CONTINUE
! RENAME PARTSYS5.SPOOL, PARTSYS6.SPOOL
! CONTINUE
! RENAME PARTSYS4.SPOOL, PARTSYS5.SPOOL
! CONTINUE
! RENAME PARTSYS3.SPOOL, PARTSYS4.SPOOL
! CONTINUE
! RENAME PARTSYS2.SPOOL, PARTSYS3.SPOOL
! CONTINUE
! RENAME PARTSYS1.SPOOL, PARTSYS2.SPOOL
!
! PRINT PARTSYS; START=4; END=4 > PARTSYSL
!
! INPUT PARTSYS_REC < PARTSYSL
!
! SETVAR PARTSYS_ID, &
! STR ( "!PARTSYS_REC", 2, POS ( " ", "!PARTSYS_REC" ) - 2 )
!
! CONTINUE
! COPY !PARTSYS_ID.OUT.HPSPOOL, PARTSYS1.SPOOL; YES
!
! SPOOLF !PARTSYS_ID; DELETE; SHOW
!
!ENDIF
!
!###########################################################
!
!## THE SPOOLF SECTION MUST BE LAST
!
!CONTINUE
!PURGE SPOOLF7.SPOOL
!CONTINUE
!RENAME SPOOLF6.SPOOL, SPOOLF7.SPOOL
!CONTINUE
!RENAME SPOOLF5.SPOOL, SPOOLF6.SPOOL
!CONTINUE
!RENAME SPOOLF4.SPOOL, SPOOLF5.SPOOL
!CONTINUE
!RENAME SPOOLF3.SPOOL, SPOOLF4.SPOOL
!CONTINUE
!RENAME SPOOLF2.SPOOL, SPOOLF3.SPOOL
!CONTINUE
!RENAME SPOOLF1.SPOOL, SPOOLF2.SPOOL
!
!CONTINUE
!PRINT !HPSPOOLID.OUT.HPSPOOL > SPOOLF1.SPOOL
!SAVE SPOOLF1.SPOOL
!
!###########################################################
!
!SET STDLIST=DELETE
!
!EOJ
+-------------------------------------------------------------------+
My mind is my own, as are my ideas and opinions.
My heart, body, and soul, however, all belong to others. Tim.
+-------------------------------------------------------------------+
Tim Ericson tericson DenKor Dental Management Corp.
Sr. Systems Analyst at denkor 503-526-4440 (my direct number)
(& Systems Manager) dot com http://www.denkor.com
Programming HP3000s since 1983! Quality dental care since 1970!
+-------------------------------------------------------------------+
UDCs and Command Files: http://www.denkor.com/hp3000/command_files
+-------------------------------------------------------------------+
|