HP3000-L Archives

May 2000, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Reisinger, Roger S" <[log in to unmask]>
Reply To:
Reisinger, Roger S
Date:
Tue, 9 May 2000 10:27:45 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (23 lines)
        Has anyone ever rebuilt the NL.PUB.SYS? I was putting my last batch
of reactive patches on last Thursday and  the SAINT failed to
build new start boot image for the NL.PUB.SYS, SAINT failed , saint reported
errors in creating START. I talked to the HPRC and they said the patch
MPEKXY6A will fix the problem. (That was one of the patches I was
installing). So I have to install MPEKXY6A before the rest of my patches.
When I did a detailed search of the patch in the patch database. The patch
just increases the space from 16mb to 20 mb. So I thought how much is
involved in cleaning the NL.PUB.SYS.
        Also, We are planning to go to 6.5 this year, will this create a
whole new NL.PUB.SYS or just add modules to it and keep all the old
branches?



Roger S. Reisinger
TYCO ELECTRONICS GROUP
MPE Technical Support (North)
PADC System Administrator
Phone:717-795-5707 ; FAX :717-795-5724
Audix (717) 986-4078 : Beeper: (717) 612-7778
E-Mail: [log in to unmask]