Hello All,

> STM Diagnostic Monitor already stopped.
> 
> STM system manager started
> STM system manager EXIT due to initialization failure
>

My bad.  

I was the engineer that last worked on CSTM for MPE/iX when I was still
a contractor at HP back in 2008.

I made the change (ODINX19A/B/C) that is alluded to in the latest HP updates

that Cathlene Mcrae posted:

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Online Diagnostic Password Requirement Notification
In September 2008, HP communicated to the installed base that HP had put in
place a process that would 
allow HP e3000 customers to access online diagnostics (cstm) without
requiring passwords after the World 
Wide End of Support on December 31, 2010. The “General Released” patch
“ODINX19” (“GR Patch”) provides this 
functionality. The GR Patch was made available in 2008 with a built-in
mechanism to disable the requirement 
for the online diagnostics password effective January 1, 2011. The GR Patch
is available for customers 
running MPE/iX versions 6.5 (ODINX19A), 7.0 (ODINX19B) and 7.5 (ODINX19C).
If you have already applied the 
GR Patch, it will automatically become effective in January.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Unfortunately, I didn't realize that DIAGMOND would check the license level,
but alas it does.

The reason the "STM INITIALIZATION FAILED" message occurs is because it
checks the license level
and now determines that an "HP" license is installed.  There is a code path
to stop diagmond
if the session has an HP license installed because the expert tools will all
be enabled.  

Since that is now the desired behavior, I Have worked out a binary patch to
solve 
the problem. Note that after the binary patch you will not need to enter the
'HLIC'
command to use the licensed tools such as the expert tools.  Note that this
is only
true for ONLINE diagnostics under STM on MPE/iX NOT OFFLINE diagnostics
under ODE.

I cannot say whether HP will want to generate an official patch for this
problem
or not.

The following binary patch will correct the problem on 6.5, 7.0 and 7.5:

Safest to create an input file to SOMPATCH:

Run editor.pub.sys
Add the following 3 lines EXACTLY (note that sompatch will not
change the instruction at offset 268 if it does not match
86a020c2, the message "Error: Old value does not match"
is displayed and no changes are made)

Hint: You might want to cut/paste them from this message.
~~~~~The 3 lines are below~~~~~~~
; Fix problem in DIAGMOND after 12/19/2010
modify ms_init_manage_sys + 268,1 86a020c2|08000240
exit
~~~~The 3 lines are above~~~~~~~~
//
K binpchin,unn

Here are the instructions for installing the binary patch:

Logon as MANAGER.SYS
Make sure DIAGMOND is not running.  If it is, it is not likely to restart
Without the patch anyway...

Run stmshut.diag.sys

Copy /usr/sbin/stm/uut/bin/sys/diagmond,DIAGMOND
Run sompatch.pub.sys;stdin=BINPCHIN;INFO='DIAGMOND'

Output should be:
Sp>; Fix problem in DIAGMOND after 12/19/2010
Sp> modify ms_init_manage_sys + 268,1 86a020c2|08000240
86a020c2|08000240
Sp>exit
Total number of patches being applied 1

END OF PROGRAM

Copy DIAGMOND,/usr/sbin/stm/uut/bin/sys/diagmond;YES

Run stmstart.diag.sys

After a few minutes, a "SHOWPROC 1;TREE;SYSTEM" should show the diagmond
process
and either the mapping processes or the memlogd, diaglogd and maybe cclogd
(A/N only).

Happy Holidays to all!

Thanks,
Gary Robillard







-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
Of Dan Barnes
Sent: Monday, December 20, 2010 9:12 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] STM System Manager Problem

Thanks, installed MANY moons ago :-).....

Dan Barnes
LCI-Lawinger Consulting
106 Central Avenue, Suite A
Osseo, MN, 55369-1243
Tel: 763-425-1639 :: Fax: 763-425-5483
Cell: 612-240-2136 :: Pager: 952-394-0132
[log in to unmask]
[log in to unmask]


-----Original Message-----
From: Craig Lalley [mailto:[log in to unmask]] 
Sent: Monday, December 20, 2010 11:11 AM
To: [log in to unmask]; Dan Barnes
Subject: Re: STM System Manager Problem

For all,

The latest CSTM patches are

 MPE/iX 6.5 == ODINX19A
 MPE/iX 7.0 == ODINX19B
 MPE/iX 7.5 == ODINX19C

-Craig





--- On Mon, 12/20/10, Dan Barnes <[log in to unmask]> wrote:

> From: Dan Barnes <[log in to unmask]>
> Subject: STM System Manager Problem
> To: [log in to unmask]
> Date: Monday, December 20, 2010, 7:30 AM
> Hi All,
> 
> This is a 989/450 HPe3000 running MPE/iX 7.0 and is patched
> up to date for quite some time now.
> 
> I have a nightly job that runs on all of our systems to
> monitor hardware.  The job blew up on Sunday and again
> this morning.  Upon initial investigation, I found that
> CSTM would not load correctly, and then found the following
> on the console:
> 
> STM Diagnostic Monitor already stopped.
> 
> STM system manager started
> STM system manager EXIT due to initialization failure
> 
> I have looked thru the archives, but only got 1 hit from
> 2005 and no helpful information.
> 
> I have tried stopping and restarting STM (STMSHUT.DIAG.SYS
> STMSTART.DIAG.SYS) to no avail.
> 
> There have been no network changes, I found nothing of
> interest in SYSLOG, and am not sure where else to look to
> ascertain what is going wrong.  Below is what I get
> when I go into CSTM.
> 
> TIA,
> Dan
> 
> - - - - - - - -
> 
> HP1659:cstm
> CSTM B8343AA.75.11  Version created FRI, MAY  9,
> 2008  8:01 AM
> Running Command File (/usr/sbin/stm/ui/config/.stmrc).
> 
> 
> This operation may take approximately one minute.
> 
> An unexpected error was encountered while attempting to
> retrieve the
> host info for hostname (hp1659.mmm.com).
> This could be due to either of the following conditions:
> 
> 
> 1) The support tool daemon "diagmond" may not be running on
> that system.
> Use the STM Startup command (in the administration menu
> under the
> file menu.)
> 
> 
> 2) The IP address for the system may be invalid or may not
> be associated
> with a valid host.  Use a valid IP address.
> 
> 
> 3) Networking may be incorrectly configured on one of the
> systems involved.
> Verify networking by comparing 'nslookup `hostname`' with
> the output
> of ifconfig of the LANs identified by lanscan.
> 
> 
> More details may be available in the System Activity Log
> and in the
> syslog on that system.
> It may be necessary to access these using the Local Unit
> Under Test (UUT) logs
> (in the administration menu under the file menu.)
> Please Refer to the UI Activity Log for more details.
> 
> An unexpected error was encountered while attempting to
> retrieve the
> host info for hostname (hp1659.mmm.com).
> This could be due to either of the following conditions:
> 
> 
> 1) The support tool daemon "diagmond" may not be running on
> that system.
> Use the STM Startup command (in the administration menu
> under the
> file menu.)
> 
> 
> 2) The IP address for the system may be invalid or may not
> be associated
> with a valid host.  Use a valid IP address.
> 
> 
> 3) Networking may be incorrectly configured on one of the
> systems involved.
> Verify networking by comparing 'nslookup `hostname`' with
> the output
> of ifconfig of the LANs identified by lanscan.
> 
> 
> More details may be available in the System Activity Log
> and in the
> syslog on that system.
> It may be necessary to access these using the Local Unit
> Under Test (UUT) logs
> (in the
> administration menu under the file menu.)
> Please Refer to the UI Activity Log for more details.
> 
> -- Information --
> MPE/iX Support Tools Manager  --  Product Number
> B8343AA, Version A.75.11
> (C) Copyright Hewlett Packard Co. 1995,2006
> All Rights Reserved
> 
> Use of this program is subject to the licensing
> restrictions described
> in "Help-->On Version".  HP shall not be liable for
> any damages resulting
> from misuse or unauthorized use of this program.
> 
> cstm>
> 
> 
> Dan Barnes
> LCI-Lawinger Consulting
> 106 Central Avenue, Suite A
> Osseo, MN, 55369-1243
> Tel: 763-425-1639 :: Fax: 763-425-5483
> Cell: 612-240-2136 :: Pager: 952-394-0132
> [log in to unmask]
> [log in to unmask]
> 
> * To join/leave the list, search archives, change list
> settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> 

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2