HP3000-L Archives

September 2000, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Dinu Iulian <[log in to unmask]>
Reply To:
Dinu Iulian <[log in to unmask]>
Date:
Tue, 26 Sep 2000 08:24:35 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (37 lines)
Hi!

My server HP3000 S932 (Panda) have MPE/iX 4.0

> To S932 (PANDA): How can I set variabiles !hpdate, !hpmonth.., because
> the sistem can't delete spoolfiles after 3 days (the program compares the
> date, when spoolfiles was created, with variabiles !hpdate, !hpmonth)?
> Now,for example, the command ":echo !hpdate" return "0" to display.


I try :

:showvar hpdate ---> 0

and

:showme ----> hpdate=0

I think is a Y2K problem, because it start when 2000 year begin.
I find a patch for this (MPELX42B for Y2K) but is for sistems with MPE/iX
6.0. and I have one with MPE/iX 4.0.
Where I can find a patch what resolves this problem (Y2K <-> hpdate), but
for MPE/iX 4.0.?

Thank you!   to all for all.

Dinu Iulian                   (www.dinuiulian.com)

System Engineer - SC Tractorul UTB SA (www.utb.com)
Brasov
ROMANIA (Transilvania)


______________________________________________
FREE Personalized Email at Mail.com
Sign up at http://www.mail.com/?sr=signup