Beside the real answer to your question (Log type 115 Console Log must be
activated) I want to
inform you that
(1) MPEX's VEAUDIT LISTLOG CONSOLE may help to capture the replies as well (but
may stop
system logging at all ...),
(2) IT/O OpC is able to filter all kind of Console Messages, especially the one's
where Operator
intervention is needed.
In between we have about 50 conditions in IT/O to filter console messages,
and different monitors to report different system stati to IT/O as well. I will
not become tired to share
our good experiences with this tool ;-) <maybe I'm spaming the list ???>
Best regards, Andreas Schmidt, CSC, Germany
rtieken <[log in to unmask]> on 08/25/98 04:03:02 PM
Please respond to rtieken <[log in to unmask]>
To: [log in to unmask]
cc: (bcc: Andreas Schmidt/HI/CSC)
Subject: CONSOLE REPLYS
Is there a way to capture operator replys to console messages through system
loging? I am almost certain we used to do this on some of the earlier versions of
MPE. Thanks in advance for any suggestions .