HP3000-L Archives

August 1998, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Andreas Schmidt <[log in to unmask]>
Reply To:
Date:
Tue, 25 Aug 1998 18:20:54 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (38 lines)
Beside the real answer to your question (Log type 115 Console Log must be
activated) I want to
inform you that

(1) MPEX's VEAUDIT LISTLOG CONSOLE may help to capture the replies as well (but
may stop
system logging at all ...),

(2) IT/O OpC is able to filter all kind of Console Messages, especially the one's
where Operator
intervention is needed.
In between we have about 50 conditions in IT/O to filter console messages,
and different monitors to report different system stati to IT/O as well. I will
not become tired to share
our good experiences with this tool ;-) <maybe I'm spaming the list ???>

Best regards, Andreas Schmidt, CSC, Germany





rtieken <[log in to unmask]> on 08/25/98 04:03:02 PM

Please respond to rtieken <[log in to unmask]>

To:   [log in to unmask]
cc:    (bcc: Andreas Schmidt/HI/CSC)
Subject:  CONSOLE REPLYS





Is there a way to capture operator replys to console messages through system
loging?  I am almost certain we used to do this on some of the earlier versions of
MPE. Thanks in advance for any suggestions .