This happens when going from an old version of BOUNCER to a newer one.
There were some changes made to the internal table kept in the data
file.
In order to convert your data file, perform the following (this is also
in BOUNCER.DOC.TECHXL)...
1. run old BOUNCER and do a KEEP BOUNSAVE
2. purge BOUNDATA.DATA.SYS
3. install new BOUNCER
4. Run new BOUNCER logged on as manager.sys
5. Do a show command (this will build new file)
6. XEQ BOUNSAVE
Jim Kilgo wrote:
>
> Has anyone ever seen this error from Bouncer and if so what is the solution?
>
> :RUN BOUNCER.PUB.TECHXL;INFO="SESSION&STOP"
>
> BOUNCER xl 1.6 (c) 1991 The Boeing Company - March 6, 1996
> ALL RIGHTS RESERVED
> BOUNCER DATA FILESIZE MISMATCH
> BOUNCER DATA NEEDS TO BE REBUILT
> *** Error occurred reading globals ***.
> ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
>
> TIA
> Jim Kilgo
> Manager Information Technologies
> Nicor Products, Inc.
> Orlando, Florida
> (407)277-0412 Ext 243
|
|
|