WHOOPS!
SHOWPROC says "no matching process"? Have you considered the possibility of a "ghost job"? This usually happens when
the session is over a LAN, but I've occasionally seen it in jobs. Particularly when they are running 3rd party products WSRN
that have low level hooks into the operating system. You didn't mention the 3rd party product you were using.
The routine is:
ABORTJOB
Multiple ABORTIO's to the output devices
Then finally FILE ZAP;DEV=offending_device and FCOPY FROM=any_file;TO=*ZAP
This last works where many other things won't, goes back to early days of MPE.
TERMDSM and OPENVIEW are also useful where appropriate
Paul Courry
On Mon, 19 Apr 1999 22:14:40 -0400, Jim Phillips wrote:
>I have a job that refuses to go away. I used the vendor's
>shutdown commands to no avail. ABORTJOB #Jnnnn is ineffective.
>SHOWPROC ;JOB=#Jnnnn says there is not matching process.
>
>Any ideas to get rid of this job *now*? Or must I go to
>work (I'm warm and snug at home now), call the other two
>locations who are using the HP3K, and reboot the machine?
>
>Thanks for any help.
>
>
>Jim Phillips Manager of Information Systems
>Voice: (330) 527-2124 Therm-O-Link, Inc.
> Fax: (330) 527-2123 PO Box 285; 10513 Freedom St.
>Email: [log in to unmask] Garrettsville, Ohio 44231
>
|
|
|