I was installing some patches on my 5.0 system and read the following
text in patch ODIJX88A.  Maybe it will be out soon.

Mike Berkowitz



~START PATCH :ODIJX88A <snip> External Symptoms, Cause, Fix Description ========================================= External Symptoms ================= ------------------------------------------------ 1. <<<<<<<<<< HP3000 Series 990 12 way is now supported. >>>>>>>>> ------------------------------------------------ 2. The logical bank for HP3000 Series 9X9 should start with     3 than 8. 3. An incorrect page status fix requires that the version of     MEMLOGP is changed so that the log file will be cleared. Cause Text ========== 1. When Series 990 12 way's syndrome register was read, only 10     processors were checked, processor 11 and 12 caused a TRAP. 2. Design error. 3. Old errors will remain in the log if the version of MEMLOGP     does not change. The invalid page status entries do not     belong to MEMLOG. <end snip> ~END PATCH:ODIJX88A****************************