I was installing some patches on my 5.0 system and read the following
text in patch ODIJX88A. Maybe it will be out soon.
Mike Berkowitz
~START PATCH :ODIJX88A
<snip>
External Symptoms, Cause, Fix Description
=========================================
External Symptoms
=================
------------------------------------------------
1. <<<<<<<<<< HP3000 Series 990 12 way is now supported. >>>>>>>>>
------------------------------------------------
2. The logical bank for HP3000 Series 9X9 should start with
3 than 8.
3. An incorrect page status fix requires that the version of
MEMLOGP is changed so that the log file will be cleared.
Cause Text
==========
1. When Series 990 12 way's syndrome register was read, only 10
processors were checked, processor 11 and 12 caused a TRAP.
2. Design error.
3. Old errors will remain in the log if the version of MEMLOGP
does not change. The invalid page status entries do not
belong to MEMLOG.
<end snip>
~END PATCH:ODIJX88A****************************
|
|
|