text/plain (23 lines)
On Wed, 4 Jan 1995 01:18:49 -0500, Wirt Atmar <[log in to unmask]> wrote:
> Subject:      Re: Data overflow printer pro...
> >Using Printer Type 18 with Xon/Xoff connected directly to a
> >DTC port, we have a problem when the spooler handles more
> >than 6 labels.
> Rodolfo,
> Are you sure that the printer is set to transmit Xon/Xoff's? And are you sure
> that the return line is actually physically present (insuring that there is
> no broken wire, bad solder joint, etc)? A printer will act exactly as you
> describe if the Xon/Xoff characters aren't reaching the DTC.
>
> Wirt Atmar
 
And if memory serves (it was a while ago) parity and 7/8 bit stuff could
mess you up pretty bad too.  The last time I used one of those printers
(early 80's) it took a while to make it work (on a Series III) and it never
would work on a 48 {or vice-versa}.
 
Finally solved the problem with a multiplexor - it was able to speak parity
with a forked tonge.
 
Good luck  --  Tony B. Shepherd  --  [log in to unmask]