Subject: | |
From: | |
Reply To: | |
Date: | Thu, 16 Dec 1999 14:30:59 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
David Knispel
[log in to unmask]
Phone: 513-248-5029
Fax: 513-248-2672
----- Original Message -----
From: Paul H Christidis <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, December 16, 1999 2:15 PM
Subject: Problem with DDS2 tape drive
> Fellow listers,
>
> For the last few weeks one of our DDS2 drives has been giving us problems.
Our
> backup utility, RoadRunner, kept reporting errors while the drive was used
for
> our weekly full backup. In every case I had to swap that drive with one
where
> RoadRunner had finished writing its share of the files and the full backup
would
> finish using the same tape.
> The message displayed at the console is:
> LDEV #x MEDIA WRITE WARNING. MEDIA MAY BE
> SUSPECT OR DEVICE IN NEED OF CLEANING.
>
> After the second week ,said drive is used once a week, I placed a call and
had
> the device replaced. I performed a test storing a few thousand sectors
using
> the new device and I got the same error. I cleaned the device and
re-tried;
> again the same error. I used a brand new tape and re-tried with the same
> results. I installed one of the other DDS2 drives in the slot of the
'suspect'
> device and the store worked. Bad drive you'd say?
>
> The CE brought a SECOND drive and I went through the same test with the
same
> result. I just repeated the test using a THIRD drive that the CE
provided,
> again with the same results. I also repeated the test using TurboStore,
in the
> event that RoadRunner was the culprit, and again the same results.
>
> Any Ideas? Any similar experiences?
>
> Regards
> Paul H. Christidis
|
|
|