Well you could create a SHUTDOWN command file. I'm not sure that we
want to put the actual command in the main MPE command stack. That may
be a can of worms from the security stand point. At least, with the
command file, you could bring your system to a good place to do the
Ctrl-A shutdown.
-----Original Message-----
From: Stan Sieler [SMTP:[log in to unmask]]
Sent: Thursday, November 19, 1998 5:18 PM
To: [log in to unmask]
Cc: [log in to unmask]
Subject: Re: [HP3000-L] System Shutdown Command Script
(take two)
It occurs to be that the right way to approach this is to make
the SHUTDOWN command a real command, not just a control-A
command.
Then, you could create a SYSSTOP script with a SHUTDOWN command
in it.
This reverses the problem statement, but solves the overall
goal.
SS