John, anytime you have any drive fail in the SYSTEM_VOLUME_SET, you have to
do an INSTALL and a RESTORE after you replace the failed drive. Under 7.5
you can use a 9gb drive for LDEV 1 and MPE will use all the space on it.
The commands don't tell you anything but reading the drive information off
of the SCSI board on the drive. But it will tell you at least the SCSI
interface is probably OK since it can read the board.
I don't understand your "dead ldev 2" question.
***************************************************************
CDR Paul Edwards USNR Ret. HP 3000 Certified Consultant
Paul Edwards & Associates
1506 Estates Way Phone: (972) 242-6660
Carrollton TX 75006 Cel : (214) 384-8728
Email: [log in to unmask] Web : www.peassoc.com
***************************************************************
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
Of John Pitman
Sent: Monday, November 08, 2010 3:17 PM
To: [log in to unmask]
Subject: Re: [HP3000-L] dead ldev 1 K959-400
We have a k959-400 (on 7.5) in Penang, and after a proper power down we seem
to have lost a disc - startup gives WARN A008 - which I think translates to
no bootable device found.
SEA gives what looks like correct, and PA also looks OK. This doesn't prove
anything about drive condition does it? I would be very surprised if there
is a SCSI issue...?
How will the recovery here differ from the case of a dead ldev 2 - no ldev 1
to install onto ? I have an SLT, there should be another on site, and data
backups. Our other K959 has a 4.5gb ldev 1 and a 9.1gb ldev 2 - if this one
is the same, there shouldn't be any issue with replacing the 4.5 with a
9.1gb should there?
Now that I look at the other K959, the IO list shows ldev1=ST34573N and
LDEV2 as ST39175LC, but discfree shows both with a device size of 35547040,
which looks like 9gb to me.....
Thanks all
Regards,
John Pitman
CAUTION: This message may contain privileged and confidential information
intended only for the use of the addressee named above. If you are not the
intended recipient of this message you are hereby notified that any use,
dissemination, distribution or reproduction of this message is prohibited.
If you have received this message in error please notify RYCO Hydraulics
Pty. Ltd. immediately. Any views expressed in this message are those of the
individual sender and may not necessarily reflect the views of RYCO
Hydraulics Pty. Ltd.
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|