Subject: | |
From: | |
Reply To: | |
Date: | Mon, 15 May 2000 16:47:48 +0100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Art,
If STREAMs had not bee enabled he would have got the following message:
Stream facility not enabled. See operator. (CIERR 32)
If you look closely at his message it looks as if the Hardware/Software
clocks are out of sync.
Regards,
Robert W.Mills (Windsong Services)
-----Original Message-----
From: Art Bahrs [mailto:[log in to unmask]]
Sent: Monday, May 15, 2000 4:04 PM
To: [log in to unmask]
Subject: Re: Problem with STREAM
Hi Kurt;
Did you enable Stream?.... Try typing STREAMS 10 on the console when logged
on as manager.sys...
Art "been there done that :) hehe" Bahrs
----- Original Message -----
From: Kurt Sager <[log in to unmask]>
To: <[log in to unmask]>
Sent: Monday, May 15, 2000 5:19 AM
Subject: Problem with STREAM
> On a simple HP/917LX system, after a disk replacement,
> and reload, we can't stream anymore.
>
> stream anyjob;in=,1
>
> or
>
> stream, ! ;in=,1
>
> results in the strange message:
>
> :stream ,!;in=,1
> Specified time is earlier than the current time.
> job(s) will be STREAMed immediately. (CIWARN 6355)
> >
>
> Why should time-now + 1 hour be earlier than the actual time???
>
> Kurt
|
|
|