You need to go into SYSDIAG, as follows:
:SYSDIAG
consolan pdev=10/4/0.1 section=2(23)
The pdev represents the hardware path of the lan/serial io portion of the
mfio card. For a 979, that should be 10/4/0.1. For a 9x8, it should be 56/56.
As pointed out earlier, you will need a SUPLICENS password - as absurd as
that may be.
At 07:51 AM 1999-08-27 -0700, Tom Renz wrote:
>I have a situation on a 979 with a Multi-Function Card that has a built-in
modem. Periodically this modem hangs and needs to be reset in order to
dial in to it from the outside. The current work around is to reboot the
system which is not practical especially if we have a large number of users
on the system. Can the modem be reset via a MPE command and/or utility to
reset the built-in modem?
>
>Any guidance would be appreciated.
>
>Tom Renz
>
>
---------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP3000 & HP9000 System Administration Specialists
300 John Street, Box 87651 Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000 Fax: 905.889.3001
Internet: [log in to unmask]
---------------------------------------------------------------------------
|
|
|